W.T.E. carried out an engineering analysis of Fusina-Venezia incineration plant, originally designed to burn MSW and now to be fed by high LHV RDF.
W.T.E. has delivered furnace mass and energetic balances in all the characteristic points of combustion diagram, verifying the combustion parameters. W.T.E. has also designed the headers and nozzles of secondary air and gas recirculation.
The plant shall be repowered reaching 20 MWth of MCR.