From 2002 to 2005 W.T.E. provided to M.E.T.A. Spa many interventions of ordinary maintenance of the furnace-boiler system . These maintenance operations were realised on the three lines of the waste to energy plant sited in Modena.
Maintenance services included:
cleaning on line by Bang & Clean system of boilers and degasers;
Measurement of wall thickness, corrosion and residual life evaluation, steam boiler tubes;
Development of technical specifications for replacement of boiler evaporator, convective section.